drprunner
Member
2017 400 Sundancer. Bought brand new in 2018. Never had a problem with the electric swim platform until a couple of months ago, when the fuse (10 amp) started blowing. So far put in a new circuit board ($950) which seemed to help for a few times of using the lift. But then started blowing fuses again. Tried a 15 amp fuse, which works but the wiring gets fairly warm. Now as soon as the battery that powers the lift is turned on, the fuse blows, even when not using the lift. So I figure the problem has to be between the battery and the fuse. Anybody else seen this problem? The company that made the electrical part of the lift is Opacmare. I've attached a few pictures of the circuit board and the wired controller.