Pictures of Kohler 5e

gerryb

Well-Known Member
TECHNICAL Contributor
Oct 12, 2006
1,974
Somers Point, NJ
Boat Info
"On Vacation"
2006 40 Sundancer
Raymarine E125 & HD Radar + Garmin 5208
Engines
QSB5.9 380 Cummins
I didn't install this but ran across some pictures of this unit which might be helpful to others in the future, for example, in showing that there are indeed 2 spark plugs. Usually this genset is placed in such a position that it is very hard to get a picture of it from more than the front side.
 

Attachments

  • kohler5e3.jpg
    kohler5e3.jpg
    25.7 KB · Views: 457
  • kohler5e5.jpg
    kohler5e5.jpg
    33.4 KB · Views: 482
  • kohler5e6.jpg
    kohler5e6.jpg
    32.6 KB · Views: 481
  • kohler5e7.jpg
    kohler5e7.jpg
    30.1 KB · Views: 462
  • kohler5e8.jpg
    kohler5e8.jpg
    33.2 KB · Views: 452
This is what a fouled plug looks like on the 5E (after being 'inspected' by one of the pups strolling down the dock)... My generator had 25 hours on it and was not running right when under a load. It would sputter and shut off under a load. Also didn't start as easy as it should. If your plug looks like this, regardless of hours, changing them would be a good idea.

I changed the plugs and run problem resolved.

This generator fouls plugs and they need to be changed every year. I would recommend that you do it AFTER spring commissioning as the initial start-up will put a nice black film on the plug from the fogging oil. I bought my plugs from Lowes, there's another post on interchangeability.

The other thing to look for is a large, oily black streak under the gen exhaust outlet after running the genset. The black gook that will be on the boat will also be on the plug.
 

Attachments

  • P7120007.jpg
    P7120007.jpg
    93 KB · Views: 378
Last edited: