- Jun 5, 2016
- 5,599
- Boat Info
- 410 Sundancer
2001
12" Axiom and 9" Axiom+ MFD
- Engines
- Cat 3126 V-Drives
I ran the generator all day on the 4th, no problems. Tried to start it yesterday, and I could hear the gen battery solenoid engage, but I did not get a green light on the start switch on the main cabin panel. No pre heat, no start.
Troubleshooting this morning, and I found the 8 amp fuse on the generator control box blown. Replaced and blown again. Oil pressure switch, 20A circuit breaker and K2 relay are the culprits according to the troubleshooting guide. Am I on the right track? Seems odd.
I have good voltage 13.5v, 20 A circuit breaker seems fine.
Troubleshooting this morning, and I found the 8 amp fuse on the generator control box blown. Replaced and blown again. Oil pressure switch, 20A circuit breaker and K2 relay are the culprits according to the troubleshooting guide. Am I on the right track? Seems odd.