2005 340 generator question

sparky90731

Member
Mar 27, 2016
88
los angeles
Boat Info
Good Day Sunshine - 2005 340 auto pilot, rib boat davit rear camera
Engines
Twin 8.1 horizons
hi
Having issues off the hook , charging batteries with generator , generator runs fine no load and then generator backfires and stuggles to charge house bank after batteries have been utilized, magnum lcd screen says its drawing 48.5 amps and the amperage does go down after a while of charging and it will stop backfiring but think its an issue with generator? genny should ramp up?
I have a magnum inverter system , i have a 6 - 6v agm bank house batteries , all new batteries last year , any thoughts , thanks
 
Assuming it's a Kohler they have known carburetor/choke issues. Check out You Tube.
 
hi
Having issues off the hook , charging batteries with generator , generator runs fine no load and then generator backfires and stuggles to charge house bank after batteries have been utilized, magnum lcd screen says its drawing 48.5 amps and the amperage does go down after a while of charging and it will stop backfiring but think its an issue with generator? genny should ramp up?
I have a magnum inverter system , i have a 6 - 6v agm bank house batteries , all new batteries last year , any thoughts
I assume the magnum is charging at 48.5A DC which is roughly 5A AC draw.

What else are you powering...total AC load might be too high. Turn off everything but inverter/charger and try that...or turn off inverter/charger and load up genny...you can eliminate if it's the Magnum or generator issue
 
thanks everthing is off and just trying to charge batteries , the kohler supposed to ramp up ? not sure , but runs fiine no load
 
Those kohler 5kw gen sets are known for eating spark plugs. Probably has NGK plugs in it now - replace those with Autolite 66 spark plugs and it will solve the issue -
 