2003 360 Sundance vent

mvoellinger

Member
Aug 26, 2008
618
Jacksonville, FL
Boat Info
2002 260DA
Engines
350 MAG w/ Bravo III
Hey guys - sitting on my friends 360 Sundancer and the bathroom and the head/galley vent doesn't work. You throw the switch for either and nothing happens. Is if the same motor, and where is it located?
 
If both power vents are inoperable, I suspect you are looking for a loose/bad connection behind the main power panel since the power vent fans are powered by a common breaker on the right side of the panel........could also be a bad breaker, I guess...... so I would start there rather than at the vent fan itself.
 
If both power vents are inoperable, I suspect you are looking for a loose/bad connection behind the main power panel since the power vent fans are powered by a common breaker on the right side of the panel........could also be a bad breaker, I guess...... so I would start there rather than at the vent fan itself.

So it's not one common fan?
 
Follow up: voltage was good at the breaker and switches. Looked behind the wall in the lower cabinet in the head, and saw the tubing combined for both vents and went up towards the cockpit. Found fan vent on external port side and pulled cabinet back directly in front of it. Whacked fan with hammer....and it started up. Theory if the previous owners (our friends, so we know this is true) never showered on the boat or cooked, so likely never ran fan. Seems to be running fine now - will wait and see, access took only ~5 minutes so no need to replace while its apart if it will run fine for another season.
 

Forum statistics

Threads
113,172
Messages
1,427,867
Members
61,086
Latest member
MrWebster
Back
Top