Kohler genset

Discussion in 'Sport Cruisers' started by John Jr, Dec 2, 2018.

  1. John Jr

    John Jr New Member

    4
    Dec 2, 2018
    1996 sea ray 330 sundancer with garmin electronics
    Twin 454 mercruiser with hurth 630 v drive
    I have a 1996 Sea Ray 330 Sundancer with a 6.5 Kohler genset when I purchased the boat someone had disconnected all the wires on the genset I found the wiring diagram from Kohler and figured out all the wires except for one which is wire number 35a the wire comes from a deltrol relay in the control box of the generator and I'm told that this relay is a add-on feature from Sea Ray all I'm asking is if anyone knows where on the genset this wire connects to it does come out of the wire loom near the oil pressure switch if that helps. This wire is nowhere located on the Kohler diagram the genset has a 22 pin connector and the Kohler diagram shows pin 17 as being empty and that is the PIN that The Wire in question goes through
     
  2. WV 320 Dancer

    WV 320 Dancer Active Member SILVER Sponsor

    169
    Oct 28, 2018
    2003 Sea Ray Sundancer 320
    Twin 350 MAG - V Drive
    We have some pretty knowledgeable folks on this site. I am sure someone will be able to offer your some guidance.
     
  3. Saverio

    Saverio Member

    999
    Aug 31, 2010
    Long island new york
    1995 330 DA
    Twin 454 Webber Carbs
    V drives
    Fresh water cooled
    if your on Facebook Join Sea ray classics and other classics. there a member there Dave lowery he is very active he rebuilds the gensets and flips them he knows them inside out.
     
  4. PlayDate

    PlayDate Well-Known Member SILVER Sponsor

    Dec 25, 2006
    Washington DC
    1994 370 Express Cruiser
    454 Mercruisers
    Without seeing it....if it is a Sea Ray only wire.....it’s purpose is probably linked to the fire suppression system. If the Fire suppression trips....it shutdowns the generator by mimicking a safety (temp, oil pressure etc) trip.

    You don’t need it to make the generator run. Any idea why the PO disconnected all the wires?
     
  5. John Jr

    John Jr New Member

    4
    Dec 2, 2018
    1996 sea ray 330 sundancer with garmin electronics
    Twin 454 mercruiser with hurth 630 v drive
    Thank you starting to get some feedback
     
  6. John Jr

    John Jr New Member

    4
    Dec 2, 2018
    1996 sea ray 330 sundancer with garmin electronics
    Twin 454 mercruiser with hurth 630 v drive
    Thanks I will give that a try
     
  7. John Jr

    John Jr New Member

    4
    Dec 2, 2018
    1996 sea ray 330 sundancer with garmin electronics
    Twin 454 mercruiser with hurth 630 v drive
    Not sure if it has to do with the fire suppression someone also told me it may be something to do with a auto changeover option no idea why the previous owner disconnected all the wires except for the generator had a shutdown problem when it got warm which I corrected but I'm assuming he was trying to correct it by disconnecting all the sensors
     