Took delivery of a 2007 sea rain 280 in the Spring. Generator was working fine. Over the summer dealer installed a new water heater and that was the extent of any activity till I just returned down. When I tried to start the generator nothing happened at all. Thinking it was a dead battery went to bilge and saw a switch on the generator Run-Auto. Pushed it to run the genny started briefly then shut off and the code LOC came up. I have owned previous boats but this has got me stumped
 

Attachments

  • 9298033F-DD31-4D06-8EBA-5074F1D3C5E7.jpeg
    9298033F-DD31-4D06-8EBA-5074F1D3C5E7.jpeg
    176.2 KB · Views: 101
  • 68A739A2-C27A-4F99-8AF0-05D0BD214B60.jpeg
    68A739A2-C27A-4F99-8AF0-05D0BD214B60.jpeg
    218 KB · Views: 98
  • 1DECCA41-F79B-4E9F-BDA5-351845865B0C.jpeg
    1DECCA41-F79B-4E9F-BDA5-351845865B0C.jpeg
    144.8 KB · Views: 96
Make sure the through hull valve is open so the generator can pull water through to cool. There is also a sensor that detects water flow through the generator that can get corroded and stay in a closed position so the generator doesn’t know water is flowing. You can replace that very cheaply.
 

Attachments

  • 588F2616-B2E3-406D-8957-5806EE3397CC.png
    588F2616-B2E3-406D-8957-5806EE3397CC.png
    1.2 MB · Views: 87
Do you think they could have closed the sea cock during water heater install?
 