48 Sundancer AC Raw Water pump power

Discussion in 'Sport Yachts/Yachts' started by jeffrey vargas, Apr 19, 2019.

  1. jeffrey vargas

    jeffrey vargas Member

    58
    Feb 4, 2019
    Sacramento, Ca
    2008 Sea Ray Sundancer 48
    Cummins QSC 8.3
    I don't have power to my raw water pump for my AC units. Anyone know where the breaker is for this AC power run? Is there a GFI somewhere? I suppose I could try and follow the power wire but it runs into a big bundle that's all tie strapped up. Thanks!
     

    Attached Files:

  2. JB MARSHALL

    JB MARSHALL Member

    122
    Aug 1, 2015
    Hudson Valley, NY
    2009-48 Sundancer
    Cummins QSC 8.3
    Jeff my guess would be to look in the engine compartment just above the battery's on the bulkhead where the main breaker panel is located. From your pic I am guessing you may have already tried that?
     
  3. CAMELLA

    CAMELLA Active Member SILVER Sponsor

    Dec 14, 2008
    Annapolis, Maryland
    2016 510 Fly
    Cummins QSM-11
    You do have the AC pump breaker on at the panel? Is the cockpit AC pump working?
     
    jeffrey vargas likes this.
  4. jeffrey vargas

    jeffrey vargas Member

    58
    Feb 4, 2019
    Sacramento, Ca
    2008 Sea Ray Sundancer 48
    Cummins QSC 8.3
    It was in fact a breaker in the main panel. It didn't look tripped but I reset them anyway and all good. Since I needed a new pump I took the opportunity to clean the bilge under the battery tray and replace some hoses. Taking the batteries and battery tray out is the only way to do this job. It took awhile longer but I think in the long it's the best approach.
     

    Attached Files:

Share This Page