370 AC Front head problems

Discussion in 'Sport Yachts/Yachts' started by Cap Clark, Oct 21, 2019.

  1. Cap Clark

    Cap Clark New Member

    4
    Oct 14, 2019
    370 AC 1998
    3116 cats
    Well woke up to a mess this morning. The front head toilet decided to take water but no vacu flush. Can't hear the pump and when I try to reset the breaker a very red power light comes on. Being new to vacuflush, I'm lost. I did get a wet vac hose down there and sucked everything out that I could reach. Nasty job, I don't recommend it. Couldn't see an obstruction. So now I'm lost.
    Anyone had this happen before and what do I doo doo?
    Cap
     
  2. stephens013

    stephens013 Active Member

    324
    Oct 8, 2009
    Ft Walton Beach, Fl
    2001 510 Sundancer
    1997 400DA Sundancer
    1994 Chalarral 310 Signature
    3196 Cat; 660 PHP
    3116 Cat; 340 PHP
    Had one kind of do this but turned out to be a leak in the hose from the value generator to the head. Vacume generator ran till it over heated then popped the breaker.
    I agree with you on not recommending this kind of clean up.

    Seems to me if the pump or the sensor on the vacume generator unit is shorted. I would disconnect the unit to see if the breaker trips. That isolates the problem between the vacume generator and boat wiring. If the wiring is ok it's just a matter of isolating the motor or the vacume sensor. Got to be one of those two units. While your at it might check the bellows and do the duck bill replacment thing. Hope yours has easy asscess.
    Take care
     
    Cap Clark likes this.
  3. bahamabreisus

    bahamabreisus Well-Known Member

    Oct 25, 2007
    Hampstead NC
    500 dancer, previous 420,390,300 dancers
    detriot 8v92
    if the breaker is tripping right away, you most likely still have a blockage. Might start at the tank end not the head end.
     
  4. boatmailster

    boatmailster Active Member

    May 13, 2007
    NY
    none to share
    none to share
    Is breaker popping? If yes then likely pump is seized, if not then you are looking at clogged hose
     
  5. Cap Clark

    Cap Clark New Member

    4
    Oct 14, 2019
    370 AC 1998
    3116 cats
    Thanks to all of you. This crapper is making me mental.
     
  6. Torgny

    Torgny New Member

    24
    Jul 5, 2017
    Sweden
    370 Sundancer 1995
    Cummins 6BTA 5.9l 370 hp Diesel
    Hi
    You can easy check the vacum genarator.
    On the top you have a lid. Take that of
    There is the sensor you see a spring there try to push it down a little bit. If it's ok the pump will start. Waste can clogg the sensor.
    I hope my english is deccent.
    I live in Sweden.
    Regards Torgny.
     
    The Bill Collector likes this.
  7. Cap Clark

    Cap Clark New Member

    4
    Oct 14, 2019
    370 AC 1998
    3116 cats
    It's awesome Torgny, thanks I'll give it a try.
     
  8. boatmailster

    boatmailster Active Member

    May 13, 2007
    NY
    none to share
    none to share
    Just make sure you know what you are doing. If you build up too much negative pressure (vaccuum), you may collapse hose.
     
    Cap Clark likes this.
  9. Torgny

    Torgny New Member

    24
    Jul 5, 2017
    Sweden
    370 Sundancer 1995
    Cummins 6BTA 5.9l 370 hp Diesel
    Hi Clark
    Do you have two toilets ?? If you have that and the other one is ok. Then I think problem can be the contact on the pedel
    When you push it down to flush.
    Torgny.
     
  10. boatmailster

    boatmailster Active Member

    May 13, 2007
    NY
    none to share
    none to share
    Even faulty water valve by foot pedal wouldnt cause lack of vaccum.
     
  11. Torgny

    Torgny New Member

    24
    Jul 5, 2017
    Sweden
    370 Sundancer 1995
    Cummins 6BTA 5.9l 370 hp Diesel
    When you push it down. The pedel should start the vacuum pump too.
    I had a same typ off problem this summer.
    Have changed the pump and sensor.
    Suddenly it didn't work. And my girlfriend sad whot did i do now. I went down in the engine room took of the lid on the generator and push down the spring on sensenor pump started again. Probably had some waste had clogg the sensor. From now on when we have done number two we flush one time extra just whit water get the system clean as possible.
    I hope my english is deccent.
    Regards Torgny.
     