2012 Sea Ray 450 Elec outlets

JCastilla

Member
Jul 20, 2021
37
Seabrook, Texas
Boat Info
2012 Sea Ray 450 Sundancer, RM Quantum2 Doppler Radome, twin Axiom 12+ MFD's
Engines
Twin Cummins QSB5.9 380 HP w/Zeus pod drives
2012 450 Sundancer, the electrical outlets on the port side only in the galley, media room and forward stateroom all don’t work. I can’t find a GFI trip button anywhere but think there must be one somewhere. No breakers are tripped. Any ideas?
 
Thanks for the reply Mitch. Just so I know what to look for, the page you reference is for a Euro boat, not sure if mine is Euro or Australian or if it even matters, but am I just looking for a receptacle with a GFI reset button on it or am I looking for something hidden behind a panel?
 
2012 450 Sundancer, the electrical outlets on the port side only in the galley, media room and forward stateroom all don’t work. I can’t find a GFI trip button anywhere but think there must be one somewhere. No breakers are tripped. Any ideas?
The one i had a hard time finding is under the bed in the stateroom where the A/C is located. Also there is one in the head up above in the cabinet
 
In my boat the aft cabin was dead and the issue was they wired the load side of the GFI wrong. Came that way from the factory because take P.O. never overnighted or used the aft cabin. Toned it out and figured it out. Hope you fine it but you may have to dig deeper.
 