    Vacuflush system won't hold pressure

    Help identifying what model my tank is. Still trouble shooting my issues but the model number is unreadable. Serial number is HTS2815967. Emailed Dometic but they said they didnt have that info. Any help so I order correct parts would he very appreciated
  2. T

    Vacuflush system won't hold pressure

    But I guess that wouldn't matter as there should be no pressure in the tank as long as the vent is properly venting, correct?
  3. T

    Vacuflush system won't hold pressure

    It appears to be. Unhooked filter and appears good flow and no blockages either way. Have not replaced this filter yet this year but was new in Aug. guess its possible its blocked some. Any chance a leaking duckbill could allow pressure to build in the tank??? Just not sure why pump...
  4. T

    Vacuflush system won't hold pressure

    its in a 2004 320…. I did notice several weeks ago the pump ran longer than normal. Just let system set thinking maybe something in a duckbill. Came back few days later and all was perfect for several weeks now snd just discovered this today. No plunger or anything with exception of pump...
  5. T

    Vacuflush system won't hold pressure

    Not since ive owned it goin on 6 years
  6. T

    Vacuflush system won't hold pressure

    Dont mean to hijack the thread, but any insight into this…. Hoping to get a little help. Whole system still seems to work fine BUT am having pressure pushed up and leaking through the saver vent and the tank level cap. Anyone ever seen these happen simultaneously?? When system builds...