Labbur
New Member
Can anyone add to this information I have obtained about water flow to my 3 Cruisair heating / air units. I have questioned that the 1,500 psi pump does not supply enough water flow to the 3 units for 100% performance. My 2008 DB has three units one 1,800 and two 1,600. The 1,800 needs 375 gals per hour and the 1,600's need 300 gals per hour each. I checked the output for each. The 1,800 on the bridge has about 190 gals and the other two cabin about 210 gals. I checked with Sea Ray and they use the 1,500 psi pump in the bridge boats and 1,000 psi on the dancers. I called Cruisair about this and in facts met them to discuss at the FT L boat show. If you want max cool need max flow. Have to admit I have not checked air tempt output but when it it above 90%, the cabin air struggles. I read several of you discussing the issues of air not cool enough. Anybody looked at this pump and water flow issues? Thanks in advance.